EX Ante ADV-system

Universiteit Twente · Onderhandeling zonder bekendmaking · 1 lots · 361686
Type
Supplies
38410000
Estimated value
Not published
To deadline
Ongoing
Knock-outs
n/a
exclusion grounds
Award basis
Best price-quality ratio
Assess manuallyconfidence low

Universiteit Twente (UT) intends to award an EX Ante ADV-system directly to Nortek Netherlands B.V. via a negotiation without prior publication. The choice is based on the absence of competition pursuant to Article 2.32 paragraph 1 sub b bullet 2 Aw 2012 and the absence of a reasonable alternative. The system must measure 3D flow velocities with a frequency of at least 32 Hz, a small measurement volume for high spatial resolution, be robust and suitable for field use including intertidal areas, and be fully pressure-waterproof up to 10 m. It must allow for autonomous deployment with an internal data logger capable of storing 3-4 months of data, an internal pressure sensor for wave information, a connection for external turbidity sensors, and low power consumption with internal batteries. The procedure is a negotiation without prior publication, which limits transparency but falls within the legal exceptions.

Supplies · Onderhandeling zonder bekendmaking · European procedure

European
Contracting authority
Contract type
Supplies
Onderhandeling zonder bekendmaking
Estimated value
Estimate not published
Submission deadline
Ongoing
Scope
European
European procedure
Lots
1
1 lots
Main CPV code
Location
Netherlands
CharacteristicsCPV 38SuppliesEU tender3D flow measurementhigh frequency sensorunderwater instrumentation

01What is being requested

Universiteit Twente (UT) intends to award an EX Ante ADV-system directly to Nortek Netherlands B.V. via a negotiation without prior publication. The choice is based on the absence of competition pursuant to Article 2.32 paragraph 1 sub b bullet 2 Aw 2012 and the absence of a reasonable alternative. The system must measure 3D flow velocities with a frequency of at least 32 Hz, a small measurement volume for high spatial resolution, be robust and suitable for field use including intertidal areas, and be fully pressure-waterproof up to 10 m. It must allow for autonomous deployment with an internal data logger capable of storing 3-4 months of data, an internal pressure sensor for wave information, a connection for external turbidity sensors, and low power consumption with internal batteries. The procedure is a negotiation without prior publication, which limits transparency but falls within the legal exceptions.

UT maintains that the contract can be awarded directly to Nortek Netherlands B.V. due to the absence of competition for technical reasons within the meaning of Article 2.32 paragraph 1 sub b bullet 2 Aw 2012. Furthermore, according to UT, there is no reasonable alternative or substitute within the meaning of Article 2.32 paragraph 3 Aw 2012 that can meet the reasonable requirements of UT set out below: 3D flow velocity measurement; High temporal resolution with a measurement frequency of at least 32 Hz; High spatial resolution due to a small measurement volume; Robust and suitable for field us

38410000Supplies
1EX Ante ADV-system

02Exclusion grounds

Exclusion grounds — consult the ESPD
  • No specific exclusion grounds were extracted. In a European tender, the mandatory and discretionary grounds of art. 2.86/2.87 of the Dutch Procurement Act almost always apply — check the European Single Procurement Document (ESPD).

03Value in context

Estimate not published

The contracting authority did not publish an estimated value — common for a large share of contracts. The EU threshold for leveringen is € 221.000, for reference.

04Likely competitors

#Likely bidderFitWins
1Bruker Nederland B.V.SME7313×
2Carl Zeiss B.V.SME6910×
3FEI Europe B.V.SME64
4JEOL (Europe) B.V.SME62
5Oxford Instruments GmbHUnknown61
6Thermo Fisher ScientificUnknown59

05Legal themes that may be relevant here

06Frequently asked questions

What technical specifications must the EX Ante ADV-system meet?
The system must measure 3D flow velocities with a frequency of at least 32 Hz and a small measurement volume for high spatial resolution. Additionally, it must be fully pressure-waterproof up to 10 meters, equipped with an internal pressure sensor for wave information, and have a connection for external turbidity sensors.
What requirements are set for autonomous deployment and power supply?
The system must be suitable for autonomous deployment with an internal data logger providing a measurement capacity of 3 to 4 months. The power supply must be via internal batteries with low power consumption.
Why was a procedure without prior publication chosen?
The contract can be awarded directly to Nortek Netherlands B.V. due to the absence of competition for technical reasons within the meaning of Article 2.32 paragraph 1 sub b bullet 2 Aw 2012. According to Universiteit Twente, there is no reasonable alternative or substitute within the meaning of Article 2.32 paragraph 3 Aw 2012 that meets the stated requirements.
For which environment is the system suitable?
The system must be robust and suitable for field use, including deployment in intertidal areas.

Automatically compiled from the official tender data and documents.

07Estimated value versus the market

p25
€ 300K
median
€ 515K
p75
€ 1,7 mln
deze opdracht

Gegunde waarden in CPV 38 · leveringen n=331